Solar Ready, before installation
The structural assessment and design certification establish the requirements for the assessed roof, mounting system and installation.
Explore Solar ReadyEngineering services
View all servicesCertification and clear pricing for installers. Roof assessments for building owners.
Commercial solar installersBuilding & portfolio ownersResidential solarProduct certificationGround-mount solarSolar Verified · after installationMore Solar Ready servicesPricing calculatorDesign and certification around your product, its loads and intended use.
Skid base designLifting certificationCustom steel structuresTelecom foundation designPortable cabinetsLight-gauge steel designPricing and scopeEngineering advice for safe, correct installation of products and equipment.
Equipment installationsBrackets and fixingsSupporting structuresProduct and site assessmentPricing and scopeProject information checklistInstallation guideNot sure where to start?
Start your projectProjects by service
View all projects
Webinar resources · 23 November 2026
Your recording, presentation slides and installer checklists for mid-scale solar as-built structural engineering reports.
Presented by Sanna Afshar, Director of Operations, with the Gamcorp team.
Watch again

Mid-scale solar reporting
Open the recording in Google Drive. If Drive reports that the video is still processing, please try again shortly.
Download and share
Follow the webinar or use the slides as a reference with your team.
Download slidesDesktop Review with an updated as-built PV layout. Includes photos and torque checks for both stages.
Download Option 1Full Inspection Desktop Review without an as-built PV layout. Includes measured photos and a location legend.
Download Option 2Share with your customer to explain the report and its implications for time, cost and planning.
Download owner informationUse the checklist for your confirmed option and system size. The Solar Verified checklists and guidance page holds the maintained documents and detailed process.
The essentials
The structural assessment and design certification establish the requirements for the assessed roof, mounting system and installation.
Explore Solar ReadyA Gamcorp engineer assesses the installation evidence against the Gamcorp design before deciding whether an as-built structural engineering report can be issued.
Solar Verified and pricingGamcorp’s checklists describe our evidence process, not a CER-prescribed photo schedule. Scope, evidence sufficiency and report issue remain subject to engineering confirmation. A report does not guarantee STC eligibility. Check the CER system classification guidance and current eligibility requirements for your project.
Choose with Engineering
The webinar called these Options A and B. The downloadable checklists use Option 1 and Option 2. Both are for installations covered by a Gamcorp-issued Solar Ready certificate.
Provide an updated as-built PV layout showing the actual arrangement, rail requirements, fixing spacings and any changes from the assessed design. Supply the supporting photos and torque-check records in the checklist.
Get the Option 1 checklistFor projects without an as-built PV layout. More detailed measured photo evidence and a location legend are required, including changes in spacing and the relevant roof zones.
Get the Option 2 checklistNeed someone to inspect the site? A separately scoped site inspection was also discussed as Option C. Contact Gamcorp to discuss the project, access, timing and fee. This is distinct from the two desktop checklist options.
Put it into practice
Send your Gamcorp job number, Solar Ready certificate, site address, system size and project stage. Allow time to review the quote and agree the evidence option with Engineering.
Follow your checklist for rails, roof fixings, changes in spacing and rail overhangs. Record the specified torque checks against the manufacturer’s requirements.
Collect the finished-array photos and panel-clamp torque records. For Option 1, provide the updated as-built PV layout and clearly identify changes from the assessed design.
Contact Gamcorp to provide the evidence. The engineer may request further information, inspection or corrective work before deciding whether to issue the report.
The online submission tool is not open to customers yet. Do not rely on a checklist QR code as a working upload pathway. Contact Gamcorp to agree how to send your evidence. If the installation is already complete and evidence is missing, discuss it with us before arranging further site work.
From the Q&A
Solar Verified is available only where Gamcorp has issued the Solar Ready certificate for the installation. For another engineer’s design or a general product certificate, contact the original engineer and discuss the site-specific assessment required.
Show what was actually installed: the array layout, rail requirements and fixing spacings for the relevant roof zones, products and orientation, and any departures from the assessed design. Follow the Option 1 checklist and confirm project-specific requirements with Engineering.
Use the current checklist for your option and system size. The webinar discussed a minimum 5% torque spot check across the relevant connections. The checklists explain the samples and records; issues found during checking may require further investigation. Use the frame manufacturer’s specified torque values.
A product certificate addresses the assessed mounting components and their stated limits. Do not assume it also assesses the supporting roof or establishes suitability for your site. Confirm what the project’s structural documentation actually covers.
See the published Solar Verified pricing, then confirm the option, scope, fee and timing with Gamcorp. Evidence quality, missing records, design changes and any further inspection affect the work needed. No universal completion time was agreed in the webinar.